954 Series | Flex-Guard H
Braided Halar™ (E-CTFE) monofilament sleeving
- Braided sleeving produced from HalarĀ® Fluoropolymer (E-CTFE) monofilament
- Halar™ is rated for use up to 150°C
- Meets FAR 29.853/FAR 25.853 requirements
- Tough yet lightweight protective sleeving
- Will not support combustion in air when placed in direct exposure to a flame
- Standard colors: Black with white spiral tracer strands or White with black spiral tracer strands
- Also available in tight weave construction
- Demonstrates excellent chemical and fungus resistance
- Resistance to abrasion and cut-through make it ideal for many industrial and electrical applications.
- Passes most tests for low flammability, limited flame travel and self-extinguishing requirements
- Open weave construction allows expansion above or below original diameter
- Good flexibility at low temperatures allowing easy flexing in any direction
- Can neatly capture a number of different sized items within one length
- Most commonly used over wires, wire bundles and harnesses, cable assemblies, flat ribbon cable, tubing and hoses where it provides a tough, durable protection
- Open weave construction allows for complete drainage, prevents condensation and provides for dissipation of heat and moisture
- Ideal for application in machine tools, automatic equipment and robotics where wires and tubes are often required to flex freely during operating cycles
- Suitable for exposure to all weather conditions.
| Size (Nominal I.D.) |
Size Range (Inches) |
Approx. Weight (LBS/1000 ft.) |
Standard Spool put-up |
|---|---|---|---|
| 1/8" | 3/32"—1/4" | 2.5 | 1000 ft. |
| 1/4" | 1/8"—3/8" | 3.8 | 1000 ft. |
| 3/8" | 1/4"—5/8" | 9.5 | 500 ft. |
| 1/2" | 3/8"—3/4" | 11.4 | 500 ft. |
| 3/4" | 1/2"—1-1/4" | 17.2 | 250 ft. |
| 1-1/4" | 7/8"—1-3/4" | 25.6 | 250 ft. |
| 1-1/2" | 1"—2" | 34.2 | 250 ft. |
| 1-3/4" | 1-1/4"—2-3/4" | 40.0 | 250 ft. |
The information provided above represents average values and is believed to be reliable. Alta Technologies, Inc. makes no warranties as to its accuracy and disclaims any liability in connection with its use. It is provided for general use only and should not be incorporated into any specific specifications.
| Property | Test Method | Performance |
|---|---|---|
| Tensile Strength | ASTM D-876 | 38,000 psi |
| Elongation | ASTM D-876 | 25% |
| Specific Gravity | ASTM D-876 | 1.68 |
| Moisture Absorption (24 Hours) | ASTM D-570 | 0.01% |
| Shrinkage @ 180°C | 3% | |
| Max. Operating Temperature | UL 224 | 150° C |
| Melt Temperature | ASTM D-2117 | 240° C |
| Low Temperature Flexibility | MIL I 23053-E | -70° C |
| Flammability | UL 224 | VW-1/FR-1 |
| UL 94 | 94 VO | |
| Flexural Modulus (10³ psi @ 73° F) | ASTM D-790 | 240 |
| Thermal Conductivity (10–4cal – cm/sec – cm2–°C) | ASTM C-177 | 3.8 |
| Limiting Oxygen Index | ASTM D-2864 | 47% |
| Smoke Density | ASTM E 622 | 94 |
| Fungus Resistance | MIL STD 810 (508) | No Growth |
| Copper Corrosivity | MIL I 23053 | No Effect |
Testing verifies that there is virtually no effect on the tensile strength or elongation of FLEX-GUARD H when exposed to the following fluids: Cleaning Fluid, De-icing Fluid, Fuel Oil, Gasoline, Hydraulic Fluid, Lubricating Oil, Salt Water and Solvents.